Location:Home > Products > Level Measurement > Water Level Measurement

HPT612 Submersible Pressure Level Transmitters

. Profiles:

HPT612 is full sealed submersible level sensor. It is made by building in high stable and reliable piezo-resistive silicon pressure sensor and high accurate circuit board into the stainless steel housing. Integrated construction and standard signal provide the user easy and convenient application in the local working place. The special cable connects with housing, can be immerged into the media for a long time.
     HPT612 level sensor has smart structure, high accuracy and good stability; it can be used for water or liquid measure and control of medicine, metallurgy, electricity, mine, city water supply and drainage and hydrology, etc. 

    HPT612 level sensor output is optional for 4-20 mA, 0-5V, and 0-10V and so on.

    For remote transfer type, please use 4-20 mA signal output.


2. Specifications:


Parameter:

HPT612

Characteristic:

Various   configurations

Corrosive   proof, explore proof and leakage proof functions

Highly-efficient   lighting protection and strong RFI & EMI resistance

High   accuracy and well stability

Applications:

a. Water   tank level measurement and control.

b. Fuel   tank level measurement and monitor (diesel, gasoline, kerosene, crude oil and   so on).

c. Liquid level   measuring in tank, rivers, lake, sea, well, tube, underground water and so   on.

d. Special occasion   such as high temperature liquid (up to 100 degree C), strongly corrosion

 liquid level measurement (request by   customized.)

Pressure Range:

0-0.1 Bar…..50 Bar / 0-1M……..500M H2O Optional

Overload:

150% F.S.

Burst Pressure

300% F.S.

Accuracy:

(Linearity; Hysteresis;

Repeatability)

±0.15%F.S (for RS485)

±0.5%F.S

±0.25%F.S

Including non-lin., rep. and hys. Optional

Long Stability:

Standard: 0.2%F.S±0.05%

Working Temp:

-40~85 OR -40~100(Customized)

Storage Temp:

-40~100

Temperature Compe:

-10~70

Medium compatible:

Compatible with 316L Stainless Steel

Electronic Wire:

2 Wires

3 Wires

3 Wires

Output:

4-20mA

0-5V

0-10 V

RS485

Power Supply:

12~36 V DC/ 3.6V   Li-battery

10~30V DC

15~36Vdc

MODBUS RTU Protocol

Load Resistance:

(U-10)/0.02 Ω

>100 kΩ

>100 kΩ

Max 255 ID

Alarm function:

With sound alarm output, optional.

Insulate resistance:

100M Ω @50V

Zero Temp. Drift:

0.03%FS/≤100kPa);  0.01%FS/(>100kPa

FS Temp. Drift:

0.03%FS/≤100kPa);  0.01%FS/(>100kPa

Electronic connection:

Sensor water proof IP68; Electronic Indicator IP65.

Response time:

10 ms

Pressure Type:

Gauge pressure; absolute pressure optional.

Certificate approving:

ExdCT6  and CE Certificate.

EMC Standard:

electromagnetic radiationEN50081-1/-2

electromagnetic   susceptibilityEN50082-2

Weight:

Net weight is about 2.5KG, Full   Packing weight is about 3.0KG (Not Include Cable)

Remarks:

3.6V Li-battery with solar panel is available   (customized!)

Special applications request by Customized


3. Part Number Selection Table:

612

Submersible   Pressure Liquid Level Transmitters


code

Pressure & Level Range

code

Pressure & Level Range

00

0…0.5

21

0…7

01

0…1.0

22

0…8

02

0…1.1

23

0…10

03

0…1.2

24

0…12

04

0…1.3

25

0…15

05

0…1.4

26

0…16

06

0…1.5

27

0…20

07

0…1.6

28

0…25

08

0…1.7

29

0…30

09

0…1.8

30

0…35

10

0…1.9

31

0…40

11

0…2.0

32

0…50

12

0…2.1

33

0…60

13

0…2.2

34

0…80

14

0…2.3

35

0…100

15

0…2.4

36

0…150

16

0…2.5

37

0…200

17

0…3

38

0…250

18

0…4

39

0…300

19

0…5

40

0…500

20

0…6

X

By Customized


Code

Pressure & Level Units

H

m H2O  (Min: 0.5 mH2O; Max:500 mH2O )

B

Bar    (Min: 0.05Bar Max:   50Bar)

MB

mBar    (Min: 50mBar Max:   50000mBar)

P

Psi     (Min:1Psi;   Max:725Psi)

F

m Fuel  (Min:0.5m; Max:500m)


Code

Pressure type

G

Gauge/Relative pressure type (universal)

A

Absolute pressure (customized)


Code

Power   Supply

S3

24 V DC (standard)

S10

1236 V DC (for code E5, E6)

S17

1030 Vdc (for code E6)


Code

Signal Output

E5

4-20 mA    (2 wires)

E6

0-5 V (3 wires)

E7

0-10 V (3 wires)

X

By Customized


Code

Measuring   Medium

CW

Water

D1

Diesel, density 0.84

D2

Diesel, density 0.83

D3

Diesel, density 0.85

D4

Diesel, density 0.86

HW

Max 100 degree C geothermal water

X

By Customized


Code

Others   Function (Optional)

N

Standard Type (Without Indicator)

TF

With Tapered Filter Covers

M1

G 1/4’’ male thread mounting type

NM

Nylon materials filter

TA

Titanium alloy materials (high cost!)

LE

With LED Indicator

LC

With LCD Indicator


Code

Accuracy

1

≤±0.5%F.S

2

≤±0.25%F.S

3

≤±0.1%F.S (high cost!)


Code

Cable   Length

003

3 Meters

XXX

By Customized

604

11

F

G

S10

E5

D1

N

1

003

Remarks

Example Part No.: 61210G1E5S10P1L11010

sdf.jpgDatasheet


Contact Us
HOLYKELL TECHNOLOGY
Lugu High-Tech Development Zone
Changsha City,Hunan,China
 admin@holykell.com
 +86-0731-89873265
 +86-0731-89873646