Location:Home > Products > Level Measurement > Water Level Measurement

HPT604 Submersible Pressure Level Transducers & Transmitters

. Profiles:

HPT604 is full sealed submersible level transducer/transmitter. It is made by building in high stable and reliable OEM piezo-resistive pressure sensor and high accurate circuit board into the stainless steel housing. Integrated construction and standard signal provide the user easy and convenient application in the local working place. The special cable connects with housing, can be immerged into the media for a long time.

For high temperature level application (up to 100 degree C), which is customized transmitters and manufacture with Germany sputtered film chips sensor, so the stability and quality very good.
       HPT604 level transducer/transmitter has compact size, light weight and good stability; it can be used for water or liquid measure and control of medicine, metallurgy, electricity, mine, city water supply and drainage and hydrology, etc. 

 

2. Specifications:


Parameter:

HPT604

Characteristic:

Various   configurations

Corrosive   proof, explore proof and leakage proof functions

Highly-efficient   lighting protection and strong RFI & EMI resistance and well   stability

Applications:

a. Water   tank level measurement and control.

b. Fuel   tank level measurement and monitor (diesel, gasoline, kerosene and so on).

c. Liquid level   measuring in tank, rivers, lake, sea, well, tube, underground water and so   on.

d. Special occasion   such as high temperature liquid (up to 100 degree C), strongly corrosion

 liquid level measurement (request by   customized.)

Pressure Range:

0-0.1 Bar…..50 Bar / 0-1M……..500M H2O Optional

Overload:

150% F.S.

Burst Pressure

300% F.S.

Accuracy:

(Linearity; Hysteresis;

Repeatability)

±0.5%F.S; ±0.25%F.S;   ±0.1%F.S

Including non-lin., rep. and hys.

Optional

Long Stability:

Standard: 0.2%F.S±0.05%

Working Temp:

-30~70 or -30~100(Customized)

Storage Temp:

-40~90OR -40~100(Customized)

Temperature Compensation:

-10~65 or -20~80(Customized)

Medium compatible:

Compatible with 316L Stainless Steel

Electronic Wire:

2 Wires

3 Wires

4 wires

Output:

4~20mA

1~5V

0~5V

0~10 V

0.5~4.5 V

Ratiometric

0-100 mV/V

RS485 Modbus RTU

Power Supply:

12~36 V DC

10~36 Vdc

15~36 Vdc

5 Vdc

10 Vdc

10~30 Vdc

polarity protection

Yes

Yes

Yes

Yes

Yes

Yes

Insulate resistance:

100M Ω@100V

Zero Temp. Drift:

0.03%FS/≤100kPa);  0.02%FS/>100kPa

FS Temp. Drift:

0.03%FS/≤100kPa);  0.02%FS/>100kPa

Electronic connection:

Fixed cable and water proof IP68

Response time:

10 ms (standard); 1 ms (Customized)

Pressure Type:

Gage pressure; Sealed gage pressure optional.

Certificate approving:

intrinsic safety or ExdIICT6 and CE Certificate approving

EMC Standard:

electromagnetic radiationEN50081-1/-2

electromagnetic   susceptibilityEN50082-2

Lighting Protection:

(optional functions)

Air conduction more than 8000V; external sensor   more than 4000 Voltage protection.

Cable optional:

Cable   materials are optional according request, we offer 3 type special cable as   follow:

PE CableWater Proof; PUR CableOil Proof; PTFE CableAnti-Corrosive.

Weight:

Net weight is about 0.35KG, Full Packing   weight is about 1.0 KG (Not Include Cable)

Remarks:

Special applications request by customized


2. Part Number Selection Table:

604

Submersible   Pressure Liquid Level Transducers&Transmitters


code

Pressure & Level Range

code

Pressure & Level Range

00

0…0.5

21

0…7

01

0…1.0

22

0…8

02

0…1.1

23

0…10

03

0…1.2

24

0…12

04

0…1.3

25

0…15

05

0…1.4

26

0…16

06

0…1.5

27

0…20

07

0…1.6

28

0…25

08

0…1.7

29

0…30

09

0…1.8

30

0…35

10

0…1.9

31

0…40

11

0…2.0

32

0…50

12

0…2.1

33

0…60

13

0…2.2

34

0…80

14

0…2.3

35

0…100

15

0…2.4

36

0…150

16

0…2.5

37

0…200

17

0…3

38

0…250

18

0…4

39

0…300

19

0…5

40

0…500

20

0…6

X

By Customized


Code

Pressure & Level Units

H

m H2O  (Min: 0.5 mH2O; Max:500 mH2O )

B

Bar    (Min: 0.05Bar Max:   50Bar)

P

Psi     (Min:1Psi;   Max:725Psi)

F

m Fuel  (Min:0.5m; Max:500m)


Code

Pressure type

G

Gauge/Relative pressure type (universal)

A

Absolute pressure (customized)


Code

Power   Supply

S3

24 V DC (standard)

S5

12 V DC (for code E0, E6)

S6

5 V DC (for code E8)

S9

1536 V DC (for code E7)

S10

1236 V DC (for code E0, E5, E6)

S17

1030 Vdc (for code E11)


Code

Signal Output

 E0

1-5 V (3 wires)

E5

4-20 mA    (2 wires)

E6

0-5 V (3 wires)

E7

0-10 V (3 wires)

E8

0.5-4.5 V (3 wires)

E11

RS485 MODBUS RTU (4 wires)

X

By Customized


Code

Measuring   Medium

CW

Water

D1

Diesel, density 0.84

D2

Diesel, density 0.83

D3

Diesel, density 0.85

D4

Diesel, density 0.86

HW

Max 100 degree C geothermal water

X

By Customized


Code

Others   Function (Optional)

N

Standard Type (with short filter)

TF

With Tapered Filter Covers

M1

G 1/4’’ male thread mounting type

NM

Nylon materials filter

TA

Titanium alloy materials (high cost!)

P

All Plastic Housing Structure


Code

Accuracy

1

≤±0.5%F.S

2

≤±0.25%F.S

3

≤±0.1%F.S (high cost!)

4

≤±0.15%F.S (by customized)


Code

Cable   Length

003

3 Meters

XXX

By Customized

604

11

F

G

S10

E5

D1

N

1

003

Remarks

Example: 60411FGS10E5D1N1003

Datasheet


Contact Us
HOLYKELL TECHNOLOGY
Lugu High-Tech Development Zone
Changsha City,Hunan,China
 admin@holykell.com
 +86-0731-89873265
 +86-0731-89873646
Privaey policy     Terms of us     Print Home© 2014 Holykell Technology