Location:Home > Products > Pressure Measurement > HPT900 Series Special purpose Pressure Transducers

HPT901 Series High Frequency Dynamic Pressure Transducer & Transmitter

1. Profiles:

In military engineering, chemical explosion test, oil exploration and exploitation and testing, materials, mechanics, civil engineering, soil mechanics. Traumtology, hydraulic power machinery and modernization of scientific experiments, such as testing instruments, which needs to measure the distortion of some changes is not high frequency, fast and steep rise in the pressure wave dynamic pressure waveform and amplitude, RMS, which requires high pressure sensors used in natural frequency, very short rise time and a good response to a wide frequency band to ensure sufficient dynamic pressure measurement accuracy, HPT901 frequency dynamic pressure transmitter is designed and developed for this, it is the company's performance by the German HELM chip, using micro-machined silicon technology enables the effective integration of small size, high natural frequency; have excellent mechanical properties of flexible, comprehensive performance is better than the piezoelectric dynamic pressure sensor, a dynamic pressure measurement of choice. 


2. Specifications:

Model:

Parameter:

HPT901

Pressure Range:

-1 Bar-0-0.1 Bar.....1000 Bar  Optional

Frequency Range:

0~1KHz~3KHz……2MHz optional.

Pressure Type:

Gauge pressure; Absolute pressure optional.

Overload:

200% F.S.

Burst Pressure

300% F.S.

Accuracy:

(Linearity Hysteresis

Repeatability)

 

±0.4%F.S

 

±0.25%F.S

 

±0.25%F.S

Intrinsic frequency

1MHz~2MHz

500KHz~1MHz

150KHz~700KHz

Bandwidth:

0 ~ 200KHz

0 ~ 20KHz

0~1KHz~3KHz

Rising time:

0 ~ 1µS

0 ~ 12µS

0 ~ 0.2 mS ~75µS

Long Stability:

Standard: 0.1%F.S±0.05%/Year

Working Temp:

40~85 (Special:   10~250)

Storage Temp:

40~120

Temp Compensation:

20~75

Medium compatible:

Compatible with 316L Stainless Steel

Electronic Wire:

2 Wire

3 Wire

Output:

4~20mA

0~5V

1~5 V

Power Supply:

12~36 V DC

12~36 V DC

12~36 V DC

Load Resistance:

≤(U-12)/0.02Ω

Insulate resistance:

>100M Ω  @100V

Zero Temp. Drift:

0.03%FS/≤100kPa,  0.02%FS/>100kPa

FS Temp. Drift:

0.03%FS/≤100kPa,  0.02%FS/>100kPa

Vibration effect:

≤±0.01%FS (XYZ axis200Hz/g)

Material of Port:

1Ci18Ni9Ti Stainless Steel

Sensor membrane:

316L Stainless Steel or Mono-crystalline silicon

Explore Proof:

Exia II CT5

Resolution:

Infinite small (theoretical), 1/100000 (general)

Electronic connection:

DIN Hirschman Terminal Box (IP65)

Fixed cable and water proof IP67 and 3 Meters

Pressure

connect port:

1/4’‘NPT male 1/2’‘NPT Female

G1/2’’; G1/4’’male optional. (by order)

Water Proof:

IP67

Response time:

According to frequency


3. Part Number Selection Table:

901

High   Frequency Dynamic Pressure Transducer & Transmitters


code

Pressure range

Ref.

code

Pressure range

Ref.

01

-1 Bar....0 Bar

G

16

0....6 Bar

G/A

02

-1 Bar....+1 Bar

G

17

0....10 Bar

G/A/S

03

-1 Bar....+2 Bar

G

18

0....15 Bar

G/A/S

04

-1 Bar....+3 Bar

G

19

0....20 Bar

G/A/S

05

-1 Bar....+4 Bar

G

20

0....25 Bar

G/A/S

06

-1 Bar....+5 Bar

G

21

0....30 Bar

G/A/S

07

-1 Bar....+6 Bar

G

22

0....35 Bar

G/A/S

08

-1 Bar....+7 Bar

G

23

0....40 Bar

G/A/S

09

-1 Bar....+9 Bar

G

24

0....50 Bar

G/A/S

10

-1 Bar....+10 Bar

G

25

0....100 Bar

G/A/S

11

0....1 Bar

G/A

26

0....150 Bar

G/A/S

12

0....2 Bar

G/A

27

0....200 Bar

G/A/S

13

0....3 Bar

G/A

28

0....300 Bar

G/A/S

14

0....4 Bar

G/A

29

0....1000 Bar

G/A/S

15

0....5 Bar

G/A

X

By Customized

G/A/S


Code

Pressure type

G

Gauge pressure type

A

Absolute pressure type


Code

Bandwidth

F1

0~1KHz~3KHz  (Accuracy ±0.25%F.S)

F2

0~20KHz  (Accuracy ±0.25%F.S)

F3

0~200KHz  (Accuracy ±0.4%F.S)


Code

Pressure connection

8

M20x1.5 male

10

1/2’‘NPT male

6

G1/4’‘ male

3

1/4’‘NPT male

9

G1/2’‘ male

X

By Customized


Code

Signal Output

E5

4-20 mA    (2 wire) max 3kHZ

E6

0-5 V (3 wire)

E0

1-5 V (3 wire)


Code

Power   Supply

S3

24 V DC (Standard)

S10

1236 V DC

S5

12 V DC


Code

Accuracy

1

±0.4%F.S

2

±0.25%F.S

3

±0.1%F.S (high cost!)


Code

Cable Length

005

5 Meters

XXX

By Customized

901

25

G

F2

10

E6

S10

2

005

Remarks

Example P/N: 90125GF210E6S102005

sdf.jpgDatasheet


Contact Us
HOLYKELL TECHNOLOGY
Lugu High-Tech Development Zone
Changsha City,Hunan,China
 admin@holykell.com