Location:Home > Products > Pressure Measurement > HPT700 & HK7 Series Smart Differential Pressure transmitters

HPT702 Economic Type Air HPT702 Economic Type Air

Characters:

Accuracy: ≤±1.0%F.S.

Wide working temperature scope

Advanced digital temperature compensation.

Highly static pressure overload

Highly strong RFI & EMI   resistance

Impact resistance and disturbance

1.5 times range standard   overload.

3 times range burst pressure

CE approving

Applications:

air differential pressure measurement

wind pipe   pressure measurement

wind machine

Industrial dust removal   equipment

Purification plant

Textile Machinery

Laboratory equipment

Blow down   expander

HAVC Air   differential pressure

And so on

 

 


1.     Specifications:

Model: Parameter:

HPT702

Pressure Range:

0-50 Pa…1000 Pa and 0 to 2kPa…1000KPa,±50Pa…±500kPa optional

Safe overload:

200%F.S.

burst Overload:

300%F.S.

Static Pressure

5Bar

Accuracy:

(Linearity Hysteresis

Repeatability)

≤±1.0%F.S.

±0.5%F.S

Optional

Long Time Stability:

Standard: 0.25%F.S

Working Temp:

-20~85

Storage Temp:

-20~85

Temperature Compensation:

0~60

Zero Point

Temp Drift:

±0.5%F.S/

Full Scale

Temp Drift:

±0.5%F.S/

Zero Error:

±0.5%F.S

Total Error:

≤±0.75%F.S  

Medium compatible:

Air or non-corrosive gas

Electronic Wire:

2 Wire

3 Wire

Output:

4~20mA

1~5V

0~5 V

Power Supply:

12 ~ 36 V DC

10~ 30 V DC

10~ 30 V DC

Electronic connection:

Fixed cable and water   proof IP65

Pressure

connect port:

RG=Ø6.5 gas   mouth or M10*1 male thread optional.

Response time:

10ms

Adjustment:

Not Support local zero   and Span calibration!

Pressure Type:

Differential Pressure (Gauge pressure)

EMC Standard:

Approving

Water Proof:

IP42

Weight:

Net   weight is about 0.1KG, Full Packing weight is about 0.35KG (Included 3   Meters Cable)

Remarks:

Special   applications request by order


2.Part Number Selection Table:

702

Gas   Differential Pressure Transducers


code

Pressure range

Ref.

code

Pressure range

Ref.

01

0 to 50 Pa

G

26

0 to 250 kPa

G

02

0 to 100 Pa

G

27

0 to 300 kPa

G

03

0 to 150 Pa

G

28

0 to 500 kPa

G

04

0 to 200 Pa

G

29

0 to 1000 kPa

G

05

0 to 250 Pa

G

30

-50Pa…0

N

06

0 to 300 Pa

G

31

-50Pa…+50Pa

N

07

0 to 350 Pa

G

32

-100Pa…0Pa

N

08

0 to 400 Pa

G

33

-100Pa…+100Pa

N

09

0 to 500 Pa

G

34

-150Pa…0Pa

N

10

0 to 600 Pa

G

35

-150Pa…+150Pa

N

11

0 to 700 Pa

G

36

-200Pa…0Pa

N

12

0 to 800 Pa

G

37

-200Pa…+200Pa

N

13

0 to 900 Pa

G

38

-300Pa…+300Pa

N

14

 0 to 1000 Pa

G

39

-500Pa…+500Pa

N

15

0 to 2 kPa

G

40

-1kPa…+1kPa

N

16

0 to 3 kPa

G

41

-2kPa…+2kPa

N

17

0 to 4 kPa

G

42

-5kPa…+5kPa

N

18

0 to 5 kPa

G

43

-10kPa…+10kPa

N

19

0 to 10 kPa

G

44

-50kPa…+50kPa

N

20

0 to 20 kPa

G

45

-100kPa…+100kPa

N

21

0 to 30 kPa

G

46

-200kPa…+200kPa

N

22

0 to 50 kPa

G

47

-250kPa…+250kPa

N

23

0 to 100 kPa

G

48

-500kPa…+500kPa

N

24

0 to 150 kPa

G

49

-1000kPa…+1000kPa

N

25

0 to 200 kPa

G

X

By Customized

G/N


Code

Pressure Type

G

Gauge Pressure

N

Negative Pressure


Code

Power Supply

S3

24 V DC (Standard)

S10

1236 V DC


Code

Pressure Process connection

32

RG=Ø6.5 mm gas mouth

11

M10*1 male thread

X

By customized


Code

Signal Output

E0

1 - 5 V (3 wire)

E5

4-20 mA (2 wire) loop Analog

E6

0-5 V (3 wire)


Code

Accuracy

0

±1%F.S

1

±0.5%F.S


Code

Cable Length (meter)

002

2 meter cable outlet

XXX

By customized

702

02

G

S3

32

E5

0

002

Remarks

Example P/N: 70202GS332E50002 

sdf.jpgDatasheet


Contact Us
HOLYKELL TECHNOLOGY
Lugu High-Tech Development Zone
Changsha City,Hunan,China
 admin@holykell.com
 +86-0731-89873265
 +86-0731-89873646
Privaey policy     Terms of us     Print Home© 2014 Holykell Technology